Ensuring Quality. Preventing Damage.
Quality assurance determines the service life of bonded and sealed facade systems. SX Engineering
supports both the investigation of existing damage and the proactive safeguarding of new projects
through structured quality assurance programmes.
Damage Analysis of Bonded and Sealed Joints
For damage cases affecting adhesive and sealant joints, we carry out systematic root-cause analyses:
visual and microscopic examination, assessment of the failure pattern (adhesive or cohesive failure),
and identification of possible causes such as UV degradation, contamination, material
incompatibility, or workmanship defects. The results are summarised in clear, defensible expert
reports.
Damage Analysis of Insulating Glass
For insulating glass units, we investigate damage patterns such as edge seal failure, moisture
ingress, gas loss, or delamination. The analysis combines on-site inspection with laboratory
examination of individual components to distinguish the actual cause of damage from mere
symptoms.
Development of Quality Assurance Programmes for Bonded and Sealed Joints and Insulating Glass
For facade contractors and insulating glass manufacturers, we develop practical quality assurance
programmes: testing frequencies, sampling plans, acceptance criteria, and documentation templates
for ongoing production. The goal is a level of testing that is economically viable while still
detecting defects early, without unnecessarily delaying production.
Execution of Quality Inspections on Load-Bearing Bonded Joints
In addition, we carry out quality inspections directly on site or at the factory — from dimensional
checks to spot-check adhesion and strength tests and documentation for acceptance protocols and evidence
for building authorities or test institutes.
Do you need an independent damage analysis or a quality assurance programme?
Get in Touch